Application: on top, underneath or at the side (2-part)
Configuration: max. 2x33 contacts K08 (1-part) or 2x68 contacts K08 (2-part)
Connection line: individual strands in a protective tube (hand plug optional)
Thermostat: 4°C falling ON; 14°C rising OFF (standard), diverse voltages
Heating (optional): interior heating (prevention of condensation), contact carrier heating, special heating
IP protection class: 54 uncoupled, 55 coupled (optional: 56 coupled)
Material:
housing / lid: cast aluminium
cap: aluminium or steel
Temperature range Environment:
Umgebung: -25°C to +50°C (standard)
-40°C or -50°C to +50°C (optional)
Temperature range Operation:
-25°C to +80°C (standard)
-40°C or -50°C to +80°C (optional)